Bx Test 7 Flashcards Preview

Question Bank > Bx Test 7 > Flashcards

Flashcards in Bx Test 7 Deck (40)
Loading flashcards...
1
Q

1:
_________ is a permanent hood which projects over an entrance to a building and is not supported by posts or columns.
A: Parapet

B: Spall

C: Marquee

D: Gypsum plank

A

C
Explanation:
A. Parapet is that portion of a wall continued above the roof line.
B. Spall the process by which masonry surfaces lose successive layers of their mass when exposed to excessive heat.
D. Gypsum plank consists of steel reinforced gypsum units with tongue and grooved galvanized steel edges. Standard planks are two inches thick, two feet wide and eight feet long. They are supported at four foot intervals under normal roof loads. A heavier gauge steel edged plate may be used for spans up to seven feet.
Taxpayer glossary

2
Q

The Systems Control Unit has a specialized task at an operation. Below are some of the procedures associated with the unit’s assignment to an incident. Which of the choices below is CORRECT?
A: The company officer will not be designated the Systems Control Unit Leader. A Chief Officer will be assigned this designation.

B: The Systems Control Unit will be assigned on all 1076’s, 10-77 2nd Alarms & 1077 Mega Hi-Rise responses.

C: The Communications Unit shall also take on the duties of the Systems Control Unit when directed by the IC.

D: The Systems Control Unit will report in to the Logistics Section Chief or directly to the Incident Commander if the Logistics Chief is not available.

A

D
Explanation:
SYSTEMS CONTROL UNIT – ICS ADDENDUM 6
A – The Officer will be designated the Systems Control Unit Leader – Sec 3
B – The IC may special call a designated unit as the Systems Control Unit. They are not automatically assigned to a box. – Section 3.
C – The Lobby Control Unit shall also take on the duties of the Systems Control Unit when directed by the IC – Sec 3.
D – 1.1

3
Q

As a Company Officer, you should be familiar with the Community Assistance Program, which assists children and adults who are experiencing trouble in the streets of NYC (harmful acts). From the following choices, select the incorrect procedure involving the Community Assistance Program.
A: While in quarters, a civilian requests assistance from the officer. The officer shall immediately notify NYPD via the FDNY dispatcher and tells the dispatcher the unit is operating at a verbal alarm to assist a civilian

B: While out of quarters, a civilian requests assistance from the officer. The officer shall immediately have the administrative battalion to respond via the FDNY dispatcher and tells the dispatcher the unit is operating at a verbal alarm to assist a civilian

C: A letterhead report, with full endorsements shall be forwarded to the Chief of Operations. This report must include the civilian’s name and the identity of the Police Officer left in charge of the civilian’s care. A Company Journal entry including the same information, must also be included

D: If a child is involved, and there is reasonable cause to suspect that a child has suffered or will suffer, abuse of maltreatment as a result of acts or omissions of a child’s parent or guardian, members are mandated to file a report. To facilitate this report, immediately request NYPD, a FDNY EMS supervisor, and an ambulance through the dispatcher. The ambulance crew will be responsible for filing the mandated report

A

B
Explanation:
AUC 3…..New, as of 8/28/2019
The officer shall immediately notify NYPD via the FDNY dispatcher and tells the dispatcher the unit is OOS and that the unit is operating at a verbal alarm to assist a civilian

4
Q

While working in Ladder 7, you receive a ticket to respond to a fire, with your unit designated as “L007H”. You would be most correct to know your unit is the?
A: Transport Backup Unit

B: Tech Decon Task Force Ladder

C: Hi-Rise Roof Team

D: CPC Unit

A

C
Explanation:
Transport Backup Unit - T
Tech Decon Task Force Ladder - D
Hi-Rise Roof Team - H
CPC Unit - C
Comm p37 H

5
Q

At fatal fire and arson investigations, security of the incident scene is of the utmost importance. Evidence must be documented, collected and preserved. Depending on the incident, the investigation may extend over a period of time. In these situations, a fire line must be established. Relatives, neighbors, spectators, the media and members of the Department shall not cross established fire lines unless authorized by the assigned ___ and/or ___.
A: Assigned Fire Marshal; Chief of Department

B: Incident Commander; Chief of Department

C: Assigned Fire Marshal; Chief of Operations

D: Incident Commander; Chief of Operations

A

C
Explanation:
Regulations 11: 11.5.22

6
Q

Ladder 99 responds to a verbal in front of quarters for an accident that results in an extrication. Members of the truck company assist in vehicle extrication. Four of the members working are CFRD qualified. What is the appropriate action for the officer to take at the completion of the response? (CORRECT)
A: All of the members of the truck company were given CFRD marks at the conclusion of the response.

B: Only the CFR qualified members of the truck company were given CFRD marks at the conclusion of the response.

C: Because the verbal extended beyond the end of the tour, the officer gave the members CFRD marks for the time beyond the end of the tour.

D: No CFRD marks were given for the response.

A

D
Explanation:
PA/ID 3-98 CFRD PAY DIFFERENTIAL
A – Only CFR certified members shall receive the differential when they respond to any of the eligible categories. 2.2.4
B – Responses to perform duties traditionally performed by these companies shall not be compensated. 2.2.5
C – The differential shall only be for the scheduled tour and not beyond. 2.3
D – Responses to perform duties traditionally performed by these companies shall not be compensated (vehicle extrication, forcible entry for EMS or CFR engines) 2.2.5
There aren’t many PA/ID type questions that’ll appear on a LT’s test, but this CFR-D & a couple of others are fair game…

7
Q

The incorrect statement made about the Company Officer and Firefighter temporary frontpiece can be found in which choice?
A: All Engine, Ladder, Rescue and Squad companies will be issued two temporary frontpieces for the company officer and four temporary frontpieces for firefighters

B: The front pieces will be stored in a location by the commanding officer and are to be used by all unassigned company officers and detailed firefighters

C: At roll call, the officer on duty is to ascertain if the unit’s officer and firefighter’s frontpieces are accounted for

D: Lost frontpieces shall be the subject of a lost property report (FS-112)

A

A
Explanation:
ONE temporary frontpiece for the company officer and THREE temporary frontpieces for firefighters…..
Also, In addition to the front pieces, an 11”X17” sign, which reminds detailed members to return the front pieces, will be issued. The sign shall be placed in an area, which is clearly visible to all members leaving quarters
AUC 299

8
Q

FDNY members have been seriously hurt from falls from portable ladders. Therefore, it’s important that all members are proficient in positioning and climbing portable ladders. Which comment below is incorrect regarding the proper way to climb a portable ladder?
A: Climb on the balls of the feet near the arch, left and right of the center line, up and down the ladder.

B: If a tool is carried, carry it close to the body or inside the ladder over the rungs in case it is accidentally dropped.

C: The underside of the beams are grasped with the hands.

D: If a tool is carried, the free hand grasps the underside of the beam.

A

B
Explanation:
B. DO NOT carry the tool close to the body or inside the ladder over the rungs because of the danger to the butt member below should the tool be accidentally dropped.
Portable Ladders 8.1

9
Q

Paperwork is reviewing a completed PCR prior to submission and made the following observations. Which action taken next to correct the errors was CORRECT?
A: A written error was observed. It was corrected by placing a single line through the incorrect entry and writing in the correction directly above it.

B: A wrong bubble was filled in. It was corrected by placing an X through it and fully darkening in the correct bubble.

C: The time recorded on the PCR was 1430 hrs. It was corrected to read 2:30 PM. Time is not expressed in Military time.

D: Errors are not permitted on the legal document. The officer discarded the form and completed another one.

A

A
Explanation:
CFRD CHAPTER 5 – DOCUMENTATION
A – Single line through the words to be corrected/omitted and write the accurate information above the word to be corrected. 3.4
B – Single line through the error and fill in the correct action. 3.4
C – All times recorded on the PCR are in military time. 3.2
D – Not Stated – Errors are to be corrected as instructed in section 3.4

10
Q

The most correct time a unit shall leave quarters for scheduled training can be found in which choice?
A: No later than 0900/1800 hours

B: No later than 0915/1815 hours

C: No later than 0930/1830 hours

D: No later than 0945/1845 hours

A

B
Explanation:
AUC 287 sec 5.1.3

11
Q

In addition to normally assigned ladder company tools, the FAST Unit shall report to the ICP with all of the following equipment except?
A: Stokes Basket with long backboard

B: Pak-Tracker

C: FAST Pak

D: Lifesaving Rope

A

D
Explanation:
Although this COULD be taken, it is not one of the REQUIRED additional tools of the FAST Unit. In addition to choices A, B, and C, the FAST Unit SHALL bring the “Search Rope” and “2:1 Rope”.
Note: A member other than the member monitoring EFAS will monitor the Pak-Tracker.
MMID Ch 2 8

12
Q

There are many variables that impact how victims are removed from a building via an aerial ladder. Which statement is incorrect?
A: If there are two victims and one is heavy and more trouble to remove and the other one ambulatory and less trouble, remove the ambulatory victim first when there is a serious fire in the front of the building.

B: Always carry small children down ladders.

C: Removal is not considered complete until the victim is removed all the way to the ground. Do not leave them on turntable.

D: If the victims requires, render first aid unless you are needed to assist in additional rescue operations.

A

A
Explanation:
A. A serious fire in the front might cut off ladder descent in a short period of time. Both members assist the most helpless victim onto the ladder and the chauffeur assists the victim below the point of danger and then to the street. While the chauffeur is slowly descending, the OV climbs out onto the ladder and assists the more ambulatory person onto the ladder and complete descent is made.

CODE: “FIRE IN THE FRONT FAT GUY FIRST”

Aerial Ladders 5.9; 5.10; 5.11; 5.13

13
Q

Communication remains an important consideration at incidents in the subway system. Which statement below is CORRECT regarding the various means of communicating underground?
A: Provided members are operating on the same repeater channel, members positioned on the opposite side of a break in the repeater zone will be able to communicate with each other.

B: Repeater antennas can be found at most emergency exits and provide reliable communication on the repeater channel inside emergency exit stairways.

C: HT relay remains the basic means of communication in the subway system and this relay should be augmented as necessary.

D: Post Radios can be considered reliable to communicate to below ground locations and in straight line areas below grade.

A

C
Explanation:
FFP UNDER RIVER RAIL OPERATIONS
A – Members on the opposite side of the break will not be able to communicate with each other. 2.9.2
B – There are no repeater antennas at most emergency exits and no repeater coverage inside most emergency exit stairways. 2.9.2
C – 2.9.1
D – Experience has shown the Post Radio may prove unreliable when communicating to below grade locations.
AUC 207 Addendum 16 - 4.3

14
Q

As a newly promoted officer, you must be well versed in all types of emergencies, including all three types of suspended scaffold emergencies. Choose the incorrect procedure followed at a Suspended Scaffold emergency.
A: If the scaffold is occupied and the need for possible rescue exists then Ladder Companies should respond with their LSR. Engine Companies LSR may also need to be utilized

B: Upon arrival, have FFs survey the roof to determine if the scaffold anchoring system has been compromised due to excessive movement. If any roof rigging is suspect, attempt to secure with LSR

C: If it is determined that the hoist motor overheated due to scaffold overload during a occupied stalled suspended scaffold emergency, then allow it to cool for at least 15 minutes. Then have the worker push the reset button

D: A LSR evolution can only lower a victim down and it is a very dangerous operation for the victim

A

B
Explanation:
Training Bulletins Emergency 4
A- 3.4
B- With Utility rope….4.2
C- 5.4
D- 5.5

15
Q

While working in Ladder 122 and performing a primary search in the cellar of a taxpayer with a medium fire condition, you notice your Can FF stumble and collapse onto the floor. As the member is now unresponsive, you correctly make which transmission after activating your EAB?
A: “Ladder 122 to Command, URGENT UNCONSCIOUS MEMBER.”

B: “Ladder 122 to Command, MAYDAY UNCONSCIOUS MEMBER.”

C: “Ladder 122 to Command, MAYDAY COLLAPSED MEMBER.”

D: “ Ladder 122 to Command, URGENT INJURED MEMBER.”

A

B
Explanation:
An Unconscious or Life Threatening Injury is a MAYDAY.
The term “COLLAPSE” is to be used to indicate STRUCTURAL FAILURE only.
FYI…you can say: “Ladder 122 to Command, MAYDAY-INJURED MEMBER or MAYDAY UNCONSCIOUS MEMBER.”
Comm 9 9.4.1 C1

16
Q

Size-up of features and conditions that may influence an operation is a critical first step at any fire or emergency. Which of the following components of size-up at an old law tenement is correct?
A: Smoke may be seen issuing from the cornice upon arrival. If so, the cornice must be opened as soon as possible to check for fire in the cockloft.

B: When forcing entrance to an apartment with two doors always choose the door in the rear.

C: A rear fire escape with no front fire escape does not necessarily mean there are railroad flat apartments at a corner building.

D: Large quantities of black smoke observed over the roof may be an indication that the fire is in an open shaft.

A

C
Explanation:
A. UNDER NO CONDITIONS should the cornice be opened for smoke. If still doubtful about the existence of fire in the cornice or cockloft, it can be examined by opening the ceiling below, or opening the returns if present.

B. When forcing entrance to an apartment with two doors, choose the door NORMALLY USED FOR ENTRANCE. Most railroad flats have a kitchen in the rear so that normal entrance doors will be the rear doors.

D. …may be an indication of fire AT OR NEAR THE TOP OF THE BUILDING, namely, top floor fire, cockloft fire, stair bulkhead fire, or a fire on the roof.

Ladders 3: 5.4.1 A; 5.4.2 C; 5.4.3 A & C

17
Q

Which of the following is INCORRECT regarding search markings at collapse operations?
A: A vertical line painted through the confirmed victim mark indicates that the secondary search in the area of the marking has been completed.

B: A circle painted around the V indicates that a potential victim has been confirmed.

C: If an area is searched and no victims are found, it still must be noted with an X to avoid duplication of searches.

D: Units coming across a single painted slash with company designation will know that search operations are in progress in this area.

A

A
Explanation:
COLLAPSE OPERATIONS – ADDENDUM 2
A – Incorrect – Vertical line confirms the removal of a victim. It is not an indication that a secondary search has been completed.
B – Correct – 5.3
C – Correct – 4.6 Note
D – Correct – 3.1/4.1

18
Q

All fire officers must be knowledgeable in the dangers of collapse, especially in Rowframes . Choose the incorrect statement made in regards to collapse in Rowframe buildings.
A: When a serious fire burns out the entire top floor, there is danger of collapse, especially in corner buildings and buildings standing alone

B: Rear walls can pull away from the building and collapse in one section into the yard

C: Collapse of sidewalls is also a danger. This is especially true where buildings within the row have been demolished. Even when walls bordering this gap are braced, the danger is still present

D: The weight of a fire escape can cause a complete collapse of an exterior wall

A

A
Explanation:
Entire FIRST FLOOR
Rowframes sec 5.4

19
Q

In order to remove a facility from the CFR-D response matrix, a company officer shall ensure
that the facility meets all the following criteria except?
A: On duty personnel are trained in CPR.

B: Trained personnel are able to provide oxygen to the patient.

C: On duty personnel are trained in the use of a defibrillator, and all the necessary equipment is available to the trained personnel.

D: All equipment and appropriately trained personnel are available 24 hours a day/5 days a week.

A

D
Explanation:
All equipment and appropriately trained personnel are available 24/7. Applies to all areas of the building.
Acronym: DOC
Defib
O2
CPR trained personnel
Comm 4 Add 1 2.1, 3.1.3

20
Q

You’re the officer of the first arriving ladder company at a fire on the first floor of peaked roof private dwelling. There are reports of someone trapped in the rear of the second floor. Your units takes the following actions. Which one is incorrect?
A: If manpower and conditions permit, have members conduct an examination of the cellar to determine if the fire started at this location.

B: Members proceeding to the side or rear must visually examine cellar windows to determine interior fire conditions. They shall not vent the windows unless orders by the ladder company officer.

C: There was no visible life hazard, so the roof/OV team performed VEIS of the rear of the first floor.

D: The first ladder company officer is the only one who can initiate the request for additional ventilation on the first floor.

A

C
Explanation:
C. If there is no visible life hazard, perform VEIS of an area on an UPPER FLOOR that is most likely to be occupied.

THIS WOULD BE THE SECOND FLOOR REAR GIVEN THE INFORMATION IN THE SCENARIO

Private Dwellings Ch 4: 5.1; 5.2

21
Q

The incorrect tactic, when operating at an old law tenement (OLT), can be found in which choice?
A: At least the first length of hose should be brought up to the fire floor and the hose strap attached to prevent hose from slipping back down the well hole of the stairway

B: If there is fire in two apartments on a floor or fire involves an apartment from front to rear, two lines may be needed on that floor

C: The absence of a fire escape on the front of an OLT will usually indicate 3-4 apartments per floor. .

D: For fires in rooms in the vicinity of a shaft, after the fire in the room has been knocked down, the line should be operated into the shaft in order to knock down the shaft fire before continuing through the apartment for knockdown and final extinguishment.

A

C
Explanation:
The absence of a fire escape on the front of an OLT will usually indicate that the apartments are railroad flats.
Multiple Dwelling Ch 1 secs 3.1.2, 3.1.3, 3.1.4, 3.7.6

22
Q

While operating at a fire in a taxpayer with 7 occupancies, you determine the original fire occupancy to be in the exact center occupancy of the row of stores. With your knowledge of appropriate sectoring and exposure identification, you should know that the occupancy two occupancies/stores to the left of the original fire occupancy should be exposure?
A: O2

B: O2A

C: O2B

D: 2

A

B
Explanation:
Since the original fire occupancy is “O”, the 1st occupancy to the left is “O2” and the second to the left is “O2A”. “O” always comes first if the “taxpayer” is the original fire building, and not simply an exposed building.
If an H-type is the original fire building and a taxpayer (with multiple occupancies) is an exposure, the “O” will come second (I.e. 2O, 2OA, 2OB. Etc.)
Comm 10 Add 2 Ills 2, 5

23
Q

While operating at a vehicle extrication, members must take certain safety precautions to avoid injury and safely remove the victim from the vehicle. Which of the following safety precautions is incorrect?
A: Always treat airbags as if they are live, observe the rule 5-10-20. The rule is at least 5” from the side airbags, 10” from the passenger airbags and 20” from the driver airbags.

B: An area of safety measuring the fully opened length and width of the jaws must be maintained.

C: Never position any part of your body between the tool and the vehicle.

D: If a member gets hydraulic fluid in their eyes, the member should flush their eyes with clean water for at least 20 minutes and immediately seek medical attention.

A

A
Explanation:
A. 5” from side, 10” from driver, 20” from passenger

CODE:
“SIDE” SHORTEST WORD = SHORTEST DISTANCE
“DRIVER” LONGER WORD = LONGER DISTANCE
“PASSENGER” LONGEST WORD = LONGEST DISTANCE

Disentanglement & Extrication 14.2; 14.4; 14.12; 14.14

24
Q

Which of the following is CORRECT regarding the Modern Fire Behavior Curve?
A: A slow Growth stage that consumes the available oxygen very quickly.

B: A rapid Growth stage that consumes the available oxygen very quickly.

C: A slow Growth stage that consumes the available oxygen very slowly.

D: A rapid Growth stage that consumes the available oxygen very slowly.

A

B
Explanation:
Ventilation sec 2.4.6

25
Q

When confronted with a dog at a fire or emergency, members are to assume all dogs are vicious. Choose the incorrect procedure when confronted with a dog.
A: A good practice is to give the dogs a means of escape; however, be alert to the possibility of the dog returning sometime later

B: A good method of detecting the presence of a dog is to shake the door vigorously

C: If necessary, use the hose stream on the dog

D: If the dog appears dangerous, it is good practice to keep it at a distance by using a purple “K” extinguisher if available

A

D
Explanation:
Training Bulletins Fires 2
A-4.4
B- 4.5
C- 4.9
D- Pressurized water extinguisher or a CO2 extinguisher if available…4.6
Also: if bitten, notify
EMS
PD
Board of Health
The Center of Animal Care and Control, if the dog is a stray
Medical Officer

26
Q

Exposed steel “I” beams are commonly used in taxpayer construction to support roof and floor joists. Of the following choices, which contains incorrect information?
A: “I” beams are often built into side or rear masonry walls, or butt the front parapet wall, where they are supported by masonry piers or iron columns at the storefronts.

B: A large, heavy “I” beam will be able to absorb more heat and its temperature will rise more slowly than a lightweight beam.

C: If “I” beams are restrained from expanding (an unlikely occurrence at roof level in taxpayers), they will buckle. Sometimes an “I” beam will push out a small section of bricks and allow fire to extend to exposures.

D: Heated steel beams or columns which are cooled by hose streams will crack or fail. Cooling a steel member with a hose line should never be attempted.

A

D
Explanation:
There is a false impression that hot steel beams or columns cooled by hose streams will crack or fail. Cooling a steel member will cause it to regain its strength and load carrying ability, and under normal circumstances, there should be no hesitation in cooling these members.
HOWEVER, if the beam has already sagged under the weight of floors or roof, firefighters should not be allowed in the possible collapse zone, whether these beams are cooled or not. The steel will contract to its original length as it is cooled and if the beam has sagged, this shortening may pull the end of the beams off their supports or twist the beam allowing the joists to drop.
Txpyr 3.6.1-3.6.4

27
Q

Buildings supplied with steam will have a steam control room filled with pipes. There will be a number of valves to control the supply of steam. Do not randomly shut steam valves inside of a supplied building. Shutting the wrong valve can cause damage to the system creating other hazardous conditions. Which of the following tactics in incorrect?
A: The inside service valve will be labeled and sealed and shall only be shut by members under the direction of Con Ed personnel.

B: Members shall not attempt to shut the building steam shutoff outside the building under any circumstances.

C: Before any valve can be reopened by Con Ed personnel the system will have to be drained.

D: Adjoining areas to the steam leak must be searched.

A

A
Explanation:
A. In an emergency, members MAY SHUT the Inside Service Valve. It will be labeled and sealed. IF POSSIBLE, wait for Con Ed steam personnel to shut the necessary valves.

Steam System Emergencies 4.4

28
Q

Knowledge of taxpayer construction is of great benefit to members. Of the following choices, all are correct except?
A: When steel beams are heated from 1000 F to 1500 F, their yield strength drops dramatically and they start to soften and fail. This temperature can be reached in five to ten minutes at a fire.

B: Columns in taxpayers can be made from wood, cast iron, lally columns (steel or cast iron) or masonry piers which support the beams. Cast iron columns are unpredictable and fail, on the average, in about thirty (30) minutes in fire endurance tests.

C: The failure of a girder is generally more serious than the failure of a column. The failure of a column in the cellar can cause the subsequent collapse of the floors and roof.

D: As many as two or three dropped ceilings may be found in a particular store. These suspended ceilings offer their own collapse potential when loaded with water or weakened by fire and are sometimes blown down by a backdraft in the cockloft.

A

C
Explanation:
The failure of a column is generally more serious than the failure of a girder or beam. The failure of a column in the cellar can cause the subsequent collapse of the floors and roof.
“A” note: …..and it is only a matter of time at an uncontrolled fire (thirty minutes for the smaller beam sections), until these beams can be heated beyond their strength limitations.
Txpyr 3.6.3, 3.7.1-3.8.1

29
Q

The only tool that can effectively cut Lexan windows can be found in which choice?
A: Pike axe

B: Oxyacetylene torch

C: Superior Air Hammer (air chisel)

D: Sawzall, with the coarse tooth wood blade

A

D
Explanation:
A- ineffective
B- ineffective
C- ineffective
Lexan cannot be broken by the use of conventional forcible entry tools. Lexan can be cut quickly and easily by using the portable power saw equipped with the carbide tipped blade. The sawzall, with the coarse tooth blade, is also effective on Lexan, but it is slower than the portable power saw
Training Bulletins Fires 4 sec 3

30
Q

A search is an orderly and systematic examination of a building or area for the purpose of locating a person, or locating fire and extension of fire. Which of the following remarks about conducting searches in an old law tenement is incorrect?
A: Upon completion of the primary searches, the secondary searches shall be conducted as soon as conditions permit and shall be conducted by units other than those who conducted the primary search of these areas.

B: Prior to proceeding above the fire, the second arriving ladder officer should ensure that the officers on the fire floor are made aware of his/her intentions so that those operating above can be warned of any situation necessitating withdrawal.

C: If you cannot gain entry into safe area on the floor above and the attack line is in position and ready to advance, you must immediately return to the fire floor, before the door to the fire area is opened.

D: On the fire floor, after opening the door, the inside team may find conditions too severe before the engine company has their line charged and are prepared to advance. In this instance they should immediately close the door.

A

D
Explanation:
D. …in this instance they should PROBE THE AREA WITH A HAND OR TOOL, THEN CLOSE THE DOOR, being careful the door does not lock.

Ladders 3: 5.5.6; 5.5.7; 5.5.8; 5.5.9

31
Q

When encountering window bars at a fire, you would be correct in all actions below except?
A: When transmitting the 10-75 for a fire in a building with window bars, include a brief description of the type of building involved and state the presence of window bars.

B: An additional Engine and Ladder shall be special called. The special called Ladder Company shall always be a Tower Ladder.

C: If there are indications that people are trapped, ensure the response of a Rescue Company.

D: An Engine on the scene or a special called Engine could provide an exterior hoseline to protect civilians or members trapped inside a building behind window bars or members removing window bars.

A

B
Explanation:
An additional Engine and Ladder shall be special called. The special called Ladder Company shall be a Tower Ladder, IF one is not assigned on the first alarm assignment.
SB 84 4.1, 4.2, 4.10

32
Q

When operating at an air/light shaft fire, the incorrect procedure can be found in which choice?
A: A hoseline should be stretched to the nearest point from which water can be directed onto fire in the shaft. Sufficient hose must be stretched to reach the upper floors of the building

B: A second hoseline may be necessary if it appears that fire might have extended into adjoining building

C: Shafts may be open or covered. It is important to ventilate those shafts with skylights or any other covering

D: For fires in rooms in the vicinity of a shaft, first operate line into the shaft knocking down all visible fire, before extinguishing fire in the room

A

D
Explanation:
For fires in rooms in the vicinity of a shaft, after the fire in the room has been knocked down, the line should be operated into the shaft in order to knock down the shaft fire before continuing through the apartment for knockdown and final extinguishment
Multiple Dwellings sec 4.7

33
Q

Members should be familiar with the location and operation of fire pumps in high rise office buildings. Of the following choices, which contains incorrect information?
A: Follow signs or directions to the pump room which is normally located on the lowest floor (cellar or sub-cellar). Locate the pump and note the gauges on the inlet and discharge lines.

B: Locate the bypass valve which should be on the discharge side of the fire pump. The discharge side can be readily identified by examining the gauges; the discharge gauge is calibrated for lower pressures than the inlet gauge.

C: The bypass valve should be in the closed position (stem in). If found to be open, it should be closed by turning in a clockwise direction.

D: The efficiency of the pump will be affected if the bypass is open. A loss of 25% can be expected in an 8” riser and a loss of 45% can be expected in a 6” riser with the bypass open.

A

B
Explanation:
Locate the bypass valve which should be on the discharge side of the fire pump. The discharge side can be readily identified by examining the gauges; the discharge gauge is calibrated for HIGHER pressures than the inlet gauge.
“C” note: Some systems are quite complex and the bypass valve is not readily discernible. If such a situation is present, it is permissible to start pump as ordered without checking bypass valve. Notify the engineer upon his/her arrival of this and any other actions taken.
HROB 4.1.2

34
Q

There is a black marker circle around each male coupling called the “creep line”. This is provided by the manufacturer and is inspected to see if the coupling is separating from the hose. This would be indicated by a movement of the line ___” away from the coupling.
A: 1/4

B: 1/3

C: 1/8

D: 3/8

A

C
Explanation:
Eng Ops Ch 3 add 3 sec 5.5.2

35
Q

What should be affixed to the inside of the front cover of the company journal?
A: A record of all drills

B: A record of all Chief visits

C: A current accurate company roster

D: A list of all current and former members with contact numbers

A

C
Explanation:
CJ 3.5

36
Q

The incorrect tool assignment/position for the second arriving Ladder Company when operating at a Brownstone type Rowframe can be found in which choice?
A: 2nd due Extinguisher FF shall consider taking two 6’ hooks in lieu of the pressurized water extinguisher to the top floor of the fire building at a top floor fire

B: 2nd arriving LCC when no longer needed at Aerial, goes into an exposure as directed by their officer

C: For a top floor fire, the 2nd OV FF shall team up with the 1st OV FF for VEIS of top floor

D: 2nd arriving Roof FF when examining returns of exposures, the returns remote from the fire should be avoided, as this action could spread the fire in the cockloft

A

A
Explanation:
Rowframes
A-Initially, the top floor of the most severely threatened exposure (for a top floor fire)….5.8.1
B- p-42
C- p-43
D- p-43

37
Q

Which of the following choices contains incorrect information regarding elevators in Older Cast-Iron Lofts?
A: Passenger and freight elevators are normally located within the area of the front wall, on either side or in the middle of the building.

B: When elevator shafts face the street, any window serving the shaft is required to display a “SHAFTWAY” sign across the outer portion of the window that is clearly visible from the street. Never place aerial or portable ladders to these shaft windows or operate streams into them.

C: Frequently, freight elevator shafts were built using terra cotta tile which can be readily breached if needed.

D: Freight elevators will not be installed with Fire Service capabilities. They are not initially used during fire operations due to their proximity to rubbish removal areas which are commonly fire origin locations.

A

B
Explanation:
AVOID placing aerial or portable ladders to these shaft windows or operating streams into them UNLESS visible fire is extending up the shaft.
“D” note: After evaluation and approval for use by the Incident Commander (IC), these elevators will allow for greater movement of members, tools and equipment due to their large size.
Loft 5.1.2

38
Q

When fire is not visible within the large area of a place of worship but is suspected to be within the concealed area of the cockloft what is the priority for water application?
A: Operate a TL from below.

B: Operate a hand line from below.

C: Operate a TL into the attic vent.

D: Operate a TL into the Rose Window.

A

C
Explanation:
NEW BULLETIN AS OF 8/15/19>br> FFP Places of Worship Fires 3.2

39
Q

As a Company Officer, you should be familiar with the “Community Engagement and Public Education Programs.” Choose the incorrect statement made in regards to these programs.
A: Visits to the firehouse are not to be scheduled during BISP periods, hydrant inspections, scheduled training activities or any other period designated by the Chief of Operations

B: All fire education programs are exempt from 10-51, except Operation Sidewalk or when ordered by the Chief of Operations

C: During “Operation Sidewalk,” the nearest engine company or ladder company is assigned to the activity for a period of one hour. The unit will remain in service by radio, and respond at the discretion of the dispatcher

D: Upon receiving a request for a Fire Safety Education event, other than a visit to Quarters, the Officer on Duty will have the requester contact the administrative battalion

A

D
Explanation:
A- 2.3
B- 2.5
C- 3.3.2
D- Contact the Fire Safety Education Unit…2.9
AUC 4 New as of 8/28/2019

40
Q

You’re a ladder company officer drilling with your members on the duties of the second to arrive ladder company at a top floor fire of a peaked roof private dwelling. Which responsibility described below is incorrect?
A: Check the floors below to ensure the fire did not start on or drop down to lower floors.

B: Members must remain on the floor below until needed.

C: At top floor fires in detached PD’s, examine the exposures for possible extension.

D: The Roof/OV team should be assigned to vent the roof when necessary.

A

C
Explanation:
C. At top floor fires in ATTACHED PD’s…

Private Dwellings Ch 4: 5.5 #6