Grab bar dimensions
42” min beside
36” min behind
33”-36” H
Directional and Informational Signage reqs
letters, font, images, mounting heights/location - may be some or all
Permanent Room signage reqs
letters, font, images, mounting heights/location - may be some or all
Toilet accessory mounting heights
18”-48” H AFF
Accessible toilet centerline dimension
16”-18”
Minimum clearance around accessible toilet
60” along rear wall
56” along side wall
Accessible toilet mounting height
17”-19” AFF to top of seat
how many sides of showers to have grab bars?
Height?
(3)
33”-36” AFF
Minimum accessible shower size
30” x 60”
accessible urinal requirements
Elongated rim; 17” H AFF
Clear floor space in restrooms and in front of which components?
30” x 48”
Lavatories, urinals, showers, and bathtubs
Accessible mirror mounting height
reflective surface 40” AFF max.
Reception/transaction counter length requirements
Over 8’-0” in length MUST have accessible height counter 36” min in length
Accessible countertop height requirements
34” max AFF
Accessible countertop clear knee space
27” H
30” W x 17” D for front approach
wall mounted control heights (front approach)
15” - 44” AFF
wall mounted control heights (side approach)
9” - 48” AFF
Accessible toe-kick
front approach elements
6” D x 9” H min
upper cabinet mounting height
44” max AFF
core drills MUST NOT be within ____ of any structural element
18”
electrical receptacle mounting height
18” AFF
GFI electrical receptacle requirement
within 36” of water source
clearance in front of electrical power panel
36”
Lavatory quantity requirements
(1) lavatory min for (1 or 2) toilets/urinals
(1) additional lavatory for every (2) additional toilets/urinals
4 toilets = 2 lavatories min.
5 toilets = 2 lavatories min.