The two basic pressurized water supply sources that a driver/operator will encounter are a ?
fire hydrant or supply hose from another pumper
p 339
Pumping at a low residual pressure (below _____ psi) while being supplied by other apparatus is dangerous. This may cause the supply hose to __________, interrupting the supply of water. It may also lead to cavitation of the pump.
20 psi / collapse
p 339
Driver/Operators should maintain a residual pressure of at least ______ psi on their master intake gauge at all times during pumping operations.
20 psi
p 340
The initial water source is often the apparatus ________ _______.
water tank
p 337
Typically the least desirable hydrants are those located on “________ ______ ________” that are served by smaller mains from only one direction.
“dead end mains”
p 340
Dead End Mains
p 340
One of the most common ways for a pumper to be supplied with water from a hydrant is by making a ?
forward hose lay
p 341
Forward Lay
p 341
Reverse Lay
p 344
Load hose with a _________ coupling to come out of the bed first when using hose with threaded couplings for a reverse lay.
male
p 344
Use double _________ adapters at the hydrant and double ________ adapters at the pump panel to execute a reverse lay using hose with threaded couplings if the hose bed has been set up for a forward lay.
female / male
p 344
Executing a reverse lay is a common method for setting up a water supply operation or relay pumping using __________ diameter hose as a supply line.
medium
p 344
With medium diameter hose, it is necessary to position a pumper at the ___________ to supplement the pressure to the supply hose.
hydrant
p 344
The reverse lay is the most direct method of supplementing _____________ ____________ or performing ____________ _____________.
hydrant pressure or performing drafting operations
p 344
Medium Diameter Hose (MDH)
p 344
Attack Pumper
p 344
Water Supply Pumper
p 344
If water is allowed to enter the tank _________ _____________, the venting may not be adequate to allow the pressure to dissipate, resulting in damage to the tank.
under pressure
p 345
Regardless of whether a particular apparatus is equipped with a check valve in the tank to pump line or a shutoff valve on the intake, the driver/operator should close the tank to pump valve after transitioning to an ?
external water supply
p 345
When the pump is full of water and the pressure in the system has stabilized with no water flowing, a reading of the pressure on the master intake gauge indicates the ___________ _____________ in the water supply system. The reading is important for estimating the remaining _________ of the hydrant as the water begins to move.
static pressure / capacity
p 346
Pumps supplying a relay operation or master stream are usually used to supply large amounts of water, requiring the use of a ____________ (___________) setting of the transfer valve.
parallel (volume)
p 346
Open all valves slowly, especially when using ________ ____________ hose. The hose must be __________ before pressure can be established.
large diameter / filled
p 346
While observing the master intake and discharge gauges, the D/O should increase the engine ______. If the master intake gauge drops below _____ psi, the throttle must not be ____________ any further because the pump may begin to cavitate.
rpm / 20 psi / increased
p 346
Several methods for preventing overheating are as follows:
p 347