HYD PUMP 1 FAIL AND HYD PUMP 2 FAIL CAUTIONS APPEAR
LAND AS SOON AS POSSIBLE. Restrict control movement to moderate rates.
COLLECTIVE BOOST SERVO HARDOVER/POWER PISTON FAILURE
① SAS/BOOST switch - Off
② FPS switch - off
PRI SERVO 1 FAIL OR PRI SERVO 2 FAIL CAUTION APPEARS
① SERVO OFF swtich - Check centered.
② If the caution appears with the SERVO OFF switch centered, move the SERVO OFF switch to turn off the malfunctioning servo.
RSVR 2 LOW AND HYD PUMP 2CAUTIONS APPEAR WITH THE BACKUP PUMP ON ADVISORY APPEARING
① AUTO FLIGHT CONTROL panel CPTR 1 and/or CPTR 2 switches (if illuminated) - Press to reset FCC
If BACKUP RSVR LOW caution also appears:
③ SERVO OFF switch - 2nd STG.
HYD PUMP 1 FAIL CAUTION APPEARS
① TAIL SERVO switch - BACKUP; then NORMAL.
RSVR 2 LOW CAUTION APPEARS
① SAS/BOOST switch - Off
② FPS switch - Verify off
HYD PUMP 2 FAIL CAUTION APPEARS
① AUTO FLIGHT CONTROL panel FAILURE RESET CPTR 1 and/or CPTR 2 switches - Press then release.
BOOST SERVO OFF CAUTION APPEARS
① SAS/BOOST switch - Off
② FPS switch - off
T/R SERVO 1 FAIL CAUTION APPEARS AND BACK UP PUMP ON ADVISORY DOES NOT APPEAR OR T/R SERVO 2 ON ADVISORY DOES NOT APPEAR
-automatic switchover did not take place
① TAIL SERVO switch - BACKUP
② BACKUP HYD PUMP switch - ON
PITCH BOOST SERVO HARDOVER
① SAS/BOOST and FPS switches - Off
RSVR 1 LOW AND HYD PUMP 1 CAUTIONS APPEAR WITH THE BACKUP PUMP ON ADVISORY APPEARING
If the BACKUP RSVR LOW caution also appears:
② SERVO OFF switch - 1st STG
HYD PUMP 1 FAIL OR HYD PUMP 2 FAIL CAUTION APPEARS AND BACKUP PUMP ADVISORY DOES NOT APPEAR
② BACKUP HYD PUMP switch - on
If BACKUP PUMP ON advisory appears:
③ Refer to HYD PUMP 1 FAIL or HYD PUMP 2 FAIL caution emergency procedure.
IF BACKUP PUMP ON advisory still does not appear