What is the purpose of a salinometer?
To give a visual indication of the presence of salt water of certain engine room machinery.
How do you test alarm and relay settings on a salinometer panel ?
What 3 factors can affect a salinometer?
A. Distance between the electrodes
B. Amount of salt in the water.
C. Temperature of water
When cleaning a salinometer what consideration should be made?
Cleaning of the probe assembly should be carried out only with the recommended chemicals laid down in the BR or local orders. Abrasive materials be used. This will only erode away the coating on the electrode and so decrease their efficiency and reduce the projected life of the probe.
What is fitted to water production units to prevent high salinity water entering tanks and what happens on failure of electrical supplies?
A dump valve Solenoid arrangement is therefore fitted, when a pre set contamination level is reached and warning relay energises. The failure of an electrical supply to a salinometer system will cause the springs to operate the solenoid valves. The arrangement is therefore made to fail safe to the dumping condition.