Is necessary before a medical technologist reports the result as RH negative
Weak D antigen
What is the use of weak D determination
To determine the presence or absence of the Du factor or weak D antigen on red cells
Weak D can be recognized most reliably by an
Indirect antihuman globulin test
Reagent used in Weak D (4)
Anti-D serum
Antihuman globulin sera
Normal saline solution (0.85% to 0.9% sodium chloride)
22% bovine serum albumin
Specimen used in weak D
Anticoagulated blood
Manner of reporting of anti-D
+
0
RH positive
RH negative / initial
Negative reaction should be further tested for the presence of weak D with the use of
Antihuman globulin test
Manner of reporting of indirect antihuman globulin test
0
+
Du negative
Du positive
Specimen used for weak D antigen determination
Anticoagulated blood sample
“U” means
Unknown
“NC” mean
Negative control
After final wash add_____of AHG
2 drops
How many times of cell washing in weak D determination
3 times
Incubate Anti-D at____for____
37 C for 15 minutes
Centrifuge AHG at_____for___
3400 rpm for 15 seconds
What is the purpose of adding combs control
To confirm validity for negative results